Enquiry
Home/News/Product sheets, manuals and tools
Product

New product sheets, manuals and online tools

The product sheets for all five spear types A, S, D, G and M have been revised, and the new manual AOB-MAN-01 for the flat spears type A (JM-AX-02) and type G (JM-GX-02) is ready. The manual AOB-MAN-03 and the service manual AOB-MAN-04 for the type S spear are now available too; the manuals for D and M will follow. All manuals use the new corporate design: A/G and S each in German, English, French, Spanish, Portuguese, Italian and Chinese. Also new: the spear length guide as a PDF and online tools around the spear: length calculator, keg simulator, spare parts with part numbers and removal and installation as an animation.

Product sheets A, S, D, G and M, manuals and spear length guide, fanned out on a desk
Product sheets A, S, D, G and M, manuals and spear length guide

The manual is aimed at keg manufacturers, breweries and companies that refurbish spears. It is divided into seven chapters: safety and warranty, product overview with components and materials, tools, installation, removal, technical data, care, troubleshooting and service, plus the technical drawings JM-AX-02 and JM-GX-02 in the appendix.

Type A and type G have the same internal parts and are installed in the same way. Only the body makes the difference: a round flange with Ø 74.5 mm on type A for A keg couplers, a triangular flange with Ø 70 mm on type G for G keg couplers. Both have the 2″–14 TPI thread to BS 84.

Each product sheet shows the spear as an exploded view with all components, in cross-section and as an assembly drawing with parts list, materials and dimensions. All five have been moved to the new corporate design.

Product sheet type AEnglish · 3 pagesv2 · Oct 2026
Product sheet type SEnglish · 3 pagesv2 · Oct 2026
Product sheet type DEnglish · 3 pagesv2 · Oct 2026
Product sheet type GEnglish · 3 pagesv2 · Oct 2026
Product sheet type MEnglish · 3 pagesv2 · Oct 2026
Manual mounting & dismounting A/GAOB-MAN-01-EN · v1.0Oct. 2026
Service manual keg spear A/GAOB-MAN-02-EN · v1.0 · disassembling, inspection, assemblingOct. 2026
Manual mounting & dismounting SAOB-MAN-03-EN · v1.1Nov. 2026
Service manual keg spear SAOB-MAN-04-EN · v1.0 · disassembling, inspection, assemblingNov. 2026
Spear Length GuideAOB-GUIDE-01-EN · v1.0 · H3, bottom clearance, length table, effects of wrong lengthsNov 2026

You will find all language versions on the downloads page.

New on aobaosi.tech

Online tools around the spear

What is in the product sheets, manuals and guide is also available interactively on the website. Many of the tools are built directly from the plant’s original CAD data.

01Calculate spear length
Choose keg type, size and system: the calculator shows the total length TL and the length to the seal SL. For DIN, Euro and Slim kegs or your own H3 dimension.
02Spear length guide (PDF)
Bottom clearance per system, a length table for common kegs and what a down tube that is too long or too short does during cleaning and dispensing.
03Keg in cross-section
A cut-open keg from the CAD data: cleaning and dispensing with a down tube that is too long, correct or too short, for A · G, S · D and M.
04Spear in 3D
On the home page, the type A spear comes apart into its six components as you scroll.
05Spare parts and parts lists
Exploded views of all five types. Click a number to see the component, part number and material.
06Removal and installation as an animation
Flat spear and Sankey spear step by step, with tools and tightening torque.
07Tools
Decompress, release, disassemble, install: the right tool for every system, plus mounting discs for the ½″ torque wrench.
08Troubleshooting
Leaking valve, pushed-out seal, foam, residual beer: causes, checks and remedies.
09Compatibility
Which keg coupler and which keg neck belong to which spear, and how long the spear must be for your keg.
10Glossary
The technical terms explained briefly, with their equivalents in other languages.
Six components

What is inside the spear

Parts in contact with beer are made of AISI 304 stainless steel, seals of EPDM to EC 1935/2004, tested by SGS to FDA 21 CFR 177.1210.

Cross-section of the type A spear
Cross-section of the type A spear
Installation and removal · Manual AOB-MAN-01

Installed in eight steps, removed in six.

Type A and type G have the same internal parts and are installed and removed in exactly the same way. Only the body differs: on the A the flange is round, on the G it is triangular.

Have ready: mounting/dismounting gun KSQ-AX-01, screw-in/screw-out and decompression tool XQ-AX-01, mounting disc LJT-AX-01 with a ½″ torque wrench, clean water. Wear safety glasses and gloves, and work only on a keg that is completely depressurised.

Installation

  1. Wet the sealWet the body seal with clean water. When wet, it slides into the keg neck without damage.
  2. Check the keg neckThe keg neck and thread must be clean and undamaged. Clean them if necessary.
  3. Check the sealThe body seal must be undamaged and correctly seated on the designated sealing surface or in the designated groove, as applicable. If it is visibly damaged, replace it straight away. As a rule, the body seal is a single-use seal: every time the spear is removed, it gets a new one.
  4. Fit the gunPress mounting/dismounting gun KSQ-AX-01 vertically onto the CO₂ valve until it audibly clicks into place. Do not press the trigger yet.
  5. Unlock and insertHold the tool firmly and turn the body anticlockwise until the down tube is free. Tilt the tube and guide it through the keg neck.
  6. LockTurn the body clockwise back to its starting position. As soon as you feel resistance, press the trigger. The gun releases.
  7. Tighten to 80 ± 5 NmTurn the spear clockwise into the keg neck, evenly and without jerking. To do this, fit mounting disc LJT-AX-01 onto the spear and tighten with a ½″ torque wrench. The screw-in/screw-out and decompression tool XQ-AX-01 can also screw the spear in if necessary, but only the torque wrench ensures the specified torque.
  8. Check alignmentRemove the tool and look down at the spear from above. The tip of the triangle on the CO₂ valve must point exactly at the line on the body. The safety lock is then locked.
Warning: The tool stays firmly on the spear during steps 4 to 6. While the safety lock is unlocked, the spring is under tension. If the triangle does not point at the line after step 8, do not use the keg: repeat steps 4 to 6 until the two match.
Retightening: after several trips to the market and back, the spear can gradually lose torque. So check empty returned kegs before refilling and retighten to 60 Nm with the mounting disc and a torque wrench. Never on a full or pressurised keg.

Removal

Danger to life: Never loosen a spear from a keg that is still under pressure. It can be ejected with great force. Vent immediately before removal, with no pause in between: pressure can build up again within just a few hours. Treat every spear as if it had no safety system, and keep your head and hands out of the area above the spear.
  1. Vent the kegPlace screw-in/screw-out and decompression tool XQ-AX-01 so that its pin sits in the opening in the spear head. Press the lever down: the pressure plunger in the middle pushes the seal down and opens the CO₂ valve. Hold until no more gas escapes.
  2. UnscrewUsing the same tool, turn the spear anticlockwise until the thread is free.
  3. Fit the gunPress mounting/dismounting gun KSQ-AX-01 vertically onto the CO₂ valve until it clicks into place. Do not press the trigger.
  4. UnlockHold the tool firmly and turn the body anticlockwise. It separates from the down tube.
  5. Take outTilt the down tube and lift the spear out of the keg neck.
  6. Lock againTurn the body clockwise back onto the down tube and press the trigger. The gun releases, and the spear is ready for storage or service.
BrauBeviale 2026, 10–12 November, Nuremberg Exhibition Centre: AOBAOSI in Hall 7A, Stand 558